Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
1.
Acta odontol. latinoam ; 35(2): 98-104, Sept. 2022. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403030

RESUMO

ABSTRACT The aim of this study was to evaluate tooth color in dental students at the University of Buenos Aires, Argentina. The participants were 184 students (157 women and 27 men) aged 21 to 33 years, mean age 24.45 (SD 2.79) years, who were in the fourth year of their dental degree. They agreed to participate through an informed consent. Exclusion criteria were: having undergone a bleaching treatment within the previous six months, presence of total or partial peripheral restoration, pigmentations, fracture, carious and non-carious lesions or absence of the right upper central incisor (1.1). A dental prophylaxis procedure was performed on the buccal surface of each 1.1 tooth with a prophylaxis brush (TDV) mounted on a low-speed rotary instrument Kavo 2068 CHC (Germany) micromotor and a Kavo LUX K201(Germany) contra-angle. Shade was measured in the middle third of each 1.1 tooth, by the same observer, using a VITA Easyshade V spectrophotometer (Zahnfabrikn Bad Säckingen, Germany), which was calibrated before each determination according to manufacturer's instructions, in the same dental unit (Sino S2316), with natural illumination, in the same time slot, without using the dental unit lamp. The results were recorded in an ad-hoc form and rates and confidence interval were obtained. Shade prevalence percentages (95% CI) were: A1: 46.2 (38.83 - 53.68); followed by A2 and B2, both with 17.39 (12.21 - 23.66); A3: 6.52 (3.41-11.11); B1: 4.35 (1.9-8.39); D2: 2.72 (0.89 - 6.23); B3: 2.17 (0.60-5.47) and C2: 1.09 (0.13-3.87); D3, C3, A3.5 and A4: 0.54 (0.01-2.99). Shades D1 and C1 were not determined in any subject. Within the conditions of this study, A1 was the most prevalent shade in central incisors, followed by A2 and B2.


RESUMEN El objetivo de este estudio fue evaluar la prevalencia de color dental en estudiantes de odontología de la Universidad de Buenos Aires (UBA). Los participantes fueron 184 estudiantes de cuarto año de la carrera de Odontología (157 mujeres y 27 hombres) de entre veintiuno y treinta tres años, con un promedio de edad de 24,45 (DE 2,79) años que aceptaron participar mediante consentimiento informado. Criterios de exclusión: quienes hayan recibido blanqueamiento en los últimos seis meses, tenían una restauración periférica total o parcial, pigmentaciones, fractura, lesiones cariosas y/o no cariosas en el incisivo central superior derecho (1.1) o éste estaba ausente. Se realizó profilaxis dental en la superficie bucal de cada 1.1 con un cepillo ad-hoc (TDV) montado en un micromotor de baja velocidad Kavo 2068 CHC (Alemania) y un contra-ángulo Kavo LUX K201 (Alemania). La medición del color se llevó a cabo en el tercio medio de cada 1.1, por el mismo observador, en la misma clínica dental, con iluminación natural en la misma franja horaria y sin utilizar la lámpara del equipo dental. Se utilizó un espectrofotómetro VITA Easyshade V (Zahnfabrikn Bad Säckingen, Alemania) que se calibró antes de cada determinación de acuerdo con las instrucciones del fabricante. Los resultados se registraron en una planilla ad-hoc y se obtuvieron tasas e intervalos de confianza. Prevalencia de colores % (IC 95%): A1: 46,2 (38,83 - 53,68), seguido de A2 y B2 ambos con 17,39 (12,21 - 23,66), A3: 6,52 (3,41-11,11), B1: 4,35 ( 1,9- 8,39), D2: 2,72 (0,89 - 6,23), B3: 2,17 (0,60-5,47) y C2: 1,09 (0,13- 3,87); D3, C3, A3.5 y A4: 0.54 (0.01-2.99) D1 y C1 no se determinaron en ningún sujeto. Dentro de las condiciones de este estudio A1 fue el color más prevalente en los incisivos centrales de estudiantes de odontología, seguido de A2 y B2.

2.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1410309

RESUMO

En el presente trabajo se realiza la estandarización del procedimiento espectrofotométrico de determinación de polisacárido capsular e intermedios de Neisseria meningitidis serogrupo X, mediante la determinación de los grupos fosfodiéster presentes en su estructura, por el método de Chen. Se realizó un análisis de los siguientes criterios para la estandarización: linealidad, precisión (repetibilidad y precisión intermedia) y exactitud. Se demostró mediante el diseño experimental y los procedimientos estadísticos empleados que el método es lineal (r > 0,99), el coeficiente de variación del factor respuesta < 5 por ciento, la desviación estándar relativa de la pendiente < 2 por ciento, no existiendo diferencia estadísticamente significativa entre el intercepto de la ecuación con respecto a cero; exacto, porque no existe diferencia estadísticamente significativa entre la concentración determinada en un material de trabajo y su concentración nominal; también demostró ser repetible, pues el coeficiente de variación de las concentraciones de la muestra evaluada (2,44; 2,43; 0,88 por ciento para las concentraciones bajas, medias y altas, respectivamente) es inferior al 3 por ciento y no existen diferencias estadísticamente significativas entre las medias de los resultados obtenidos por dos analistas, evaluados durante cuatro días a tres niveles de concentración. La precisión intermedia es satisfactoria(AU)


The present work comprises the standardization a spectrophotometric procedure for assessing Neisseria meningitidis, serogroup X capsular polysaccharide and their intermediates of modification, the phosphodiesters groups present in its structure, based on Chen method. An analysis of the following standardization criteria was performed: linearity, precision (repeatability and intermediate precision) and accuracy. It was demonstrated through the experimental design and the statistical procedures used that the method is linear (r > 0.99), the coefficient of variation of the response factor < 5 percent, the relative standard deviation of the slope < 2 percent, with no statistically significant difference between the intercept of the equation with respect to zero; exact, because there is no statistically significant difference between the concentration determined in a work material and its nominal concentration; it also proved to be repeatable, because the coefficient of variation of the concentrations of the sample (2.44; 2.43; 0.88 percent for low, medium and high concentrations respectively) is less than 3 percent and there is no statistically significant difference between the means of the results obtained by two analysts, evaluated for four days at three concentration levels. Its intermediate precision was satisfactory(AU)


Assuntos
Humanos , Masculino , Feminino , Padrões de Referência , Espectrofotometria/métodos , Fatores de Virulência , Infecções Meningocócicas/diagnóstico , Infecções Meningocócicas/epidemiologia , Inibidores de Fosfodiesterase
3.
Rev. bras. ciênc. vet ; 29(2): 101-106, abr./jun. 2022. il.
Artigo em Português | LILACS, VETINDEX | ID: biblio-1399563

RESUMO

O objetivo deste trabalho foi analisar e correlacionar os resultados de qualidade do leite cru refrigerado de dez propriedades rurais de Viçosa (MG) obtidos por métodos de referências do Ministério da Agricultura, Pecuária e Abastecimento e por espectrofotômetros de luz infravermelha em três laboratórios (A, B e C) credenciados pelo mesmo órgão de fiscalização. As amostras de leite foram analisadas quanto à contagem bacteriana, contagem de células somáticas (CCS) e teores de gordura, proteína e extrato seco desengordurado (ESD). Não houve discordância de amostras de leite quanto aos teores de proteína e gordura. Porcentagens diferentes de discordância foram observadas entre os resultados dos laboratórios e método de referência quanto à CCS, contagem bacteriana e teores de ESD. Os teores médios de proteína dos laboratórios A e B e os teores médios de ESD de todos laboratórios não foram estatisticamente iguais (p<0,05) aos teores obtidos pelo método de referência. Os teores de gordura obtidos no laboratório B não tiveram correlação estatística (p>0,05) com os teores obtidos pelo método de referência. Observou-se que as CCS e contagens bacterianas médias de todos os laboratórios foram estatisticamente iguais (p>0,05) e correlacionadas (p<0,05) às contagens médias obtidas pelos métodos de referência. Conclui-se que os teores de proteína em dois laboratórios e ESD em todos os laboratórios não são equivalentes com os métodos de referência do MAPA. É importante que os laboratórios revejam a calibração dos seus equipamentos quanto à quantificação dos teores de sólidos do leite.


The objective of this study was to analyze and to correlate the results of refrigerated raw milk quality in ten farms of Viçosa (MG). The milk was analyzed by the Ministério da Agricultura, Pecuária e Abastecimento standard methods and by infrared spectrophotometers in three laboratories (A, B and C) accredited by the same institution. The milk samples were analyzed for bacterial counts, somatic cell count (SCC) and fat, protein and solids not fat (SNF) tenors. There were no disagreement milk samples as the protein and fat tenors. Different percentages of disagreement were observed between the results of laboratory and standard method as the SCC, bacterial count and SNF tenor. The protein mean tenor of A and B laboratories and the SNF mean tenor of all laboratories were not statistically equal (p<0.05) the tenors obtained by standard method. The fat tenors obtained in B laboratory were not statistically correlated (p>0.05) with tenors obtained by the standard method. It was observed that the means of SCC and bacterial counts of all laboratories were statistically the same (p>0.05) and correlated (p<0.05) to the means counts obtained by standard methods. It is concluded that the protein tenors in two laboratories and SNF in all laboratories are not equivalent with the reference methods of MAPA. It is important that laboratories review the calibration of the equipment on the quantification of milk solids tenors.


Assuntos
Controle de Qualidade , Espectrofotômetros , Normas de Qualidade de Alimentos , Leite/normas , Carga Bacteriana/normas , Alimentos Crus/análise
4.
Alerta (San Salvador) ; 5(1): 64-73, ene. 28, 2022. tab
Artigo em Espanhol | BISSAL, LILACS | ID: biblio-1354468

RESUMO

Los trastornos hipertensivos asociados al embarazo constituyen uno de los síndromes de mayor interés a escala mundial, cerca de 600 000 mujeres mueren anualmente por causas relacionadas. La Organización Mundial de la Salud considera que la incidencia de preeclampsia es siete veces mayor en los países en vías de desarrollo en comparación a los industrializados (2,8 % y 0,4 %, respectivamente). El estrés oxidativo es una de las principales causas asociadas a la preeclampsia, cuyo diagnóstico y manejo adecuado y oportuno son medidas eficaces para disminuir la tasa de morbimortalidad, por lo que diversos autores se han centrado en la búsqueda de biomarcadores predictores de estrés oxidativo entre los cuales encontramos: especies reactivas del ácido tiobarbitúrico, superóxido, catalasa, superóxido dismutasa y glutatión peroxidasa. El presente trabajo describe los principales biomarcadores de estrés oxidativo estudiados mediante la técnica espectrofotométrica debido a que es económica, rápida y precisa


Hypertensive disorders associated with pregnancy are one of the syndromes of greatest interest worldwide, nearly 600,000 women die annually from related causes. The World Health Organization considers that the incidence of preeclampsia is seven times higher in developing countries compared to industrialized ones (2.8% and 0.4%, respectively). Oxidative stress is one of the main causes associated with preeclampsia, whose proper and timely diagnosis and management are effective measures to reduce the morbidity and mortality rate, which is why various authors have focused on the search for predictive biomarkers of oxidative stress among which we find: reactive species of thiobarbituric acid, superoxide, catalase, superoxide dismutase and glutathione peroxidase. The present work describes the main biomarkers of oxidative stress studied by means of the spectrophotometric technique because it is cheap, fast and precise


Assuntos
Pacientes , Pré-Eclâmpsia , Espectrofotometria , Mulheres , Estresse Oxidativo , Indicadores de Morbimortalidade , Morbidade , Métodos
5.
Dental press j. orthod. (Impr.) ; 27(6): e2220352, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1430266

RESUMO

ABSTRACT Objective: This study aimed to assess the effects of three methods of adhesive remnant removal (carbide bur and low speed handpiece, carbide bur and high speed handpiece, and zircon-rich glass fiber reinforced composite bur), after orthodontic bracket debonding, on tooth color and enamel surface roughness. Methods: Ninety sound premolar teeth were selected. The baseline tooth color was assessed using Vita spectrophotometer. The teeth were subjected to bracket bonding processes and then randomly divided into three equal groups. In each group, composite remnant was removed by one of the three methods of adhesive removal, and the teeth were then subjected to color assessment again. To measure the surface roughness, a scanning electron microscope (SEM) with x400 magnification was used. Results: ANOVA showed that the effect of the three methods of adhesive remnant removal on ∆L, ∆b and ∆E was statistically significant (p=0.01), but without significant effect on ∆a. Comparison of the means showed that composite bur and high speed carbide bur yielded the highest ∆E (p=0.05), and had a significant difference when compared to carbide bur and low speed handpiece. The highest ∆L and ∆b values belonged to samples approached with composite bur and carbide bur with high speed handpiece, respectively. SEM analysis showed that the composite bur created a very smooth surface, compared to the other two methods. Conclusion: Zircon-rich glass fiber reinforced composite created the smoothest enamel surface and highest color change, when compared to the other two methods.


RESUMO Objetivo: O presente estudo teve como objetivo avaliar os efeitos de três métodos de remoção de adesivo remanescente (broca carbide e peça de mão em baixa rotação, broca carbide e peça de mão em alta rotação, e broca de compósito reforçado com fibra de vidro rica em zircônia), após a descolagem de braquetes ortodônticos, sobre a cor dos dentes e rugosidade superficial do esmalte. Métodos: Noventa pré-molares hígidos foram selecionados. A cor inicial dos dentes foi avaliada usando um espectrofotômetro Vita. Os dentes foram submetidos à etapa de colagem dos braquetes e, então, divididos aleatoriamente em três grupos. Em cada grupo, o adesivo remanescente foi removido usando um dos três métodos de remoção, e os dentes foram novamente submetidos à avaliação de cor. Para medir a rugosidade superficial dos dentes, foi usado um microscópio eletrônico de varredura (MEV) com aumento de 400x. Resultados: A ANOVA mostrou que os três métodos de remoção do adesivo remanescente tiveram efeito estatisticamente significativo (p=0,01) em ∆L, ∆b e ∆E, mas sem efeito significativo em ∆a. A comparação das médias mostrou que a broca de compósito e a broca carbide em alta rotação produziram o maior ∆E (p=0,05) e tiveram uma diferença significativa quando comparadas com a broca carbide e a peça de mão em baixa rotação. Os maiores valores de ∆L e ∆b foram encontrados, respectivamente, nos grupos com broca de compósito e broca carbide usando peça de mão em alta rotação. A análise MEV mostrou que o uso da broca de compósito resultou em uma superfície muito lisa, em comparação com os outros dois métodos. Conclusão: Em comparação aos outros métodos, a broca de compósito reforçado com fibra de vidro rica em zircônia criou a superfície de esmalte mais lisa e resultou em uma maior mudança de cor.

6.
Int. j interdiscip. dent. (Print) ; 14(2): 158-161, ago. 2021. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1385206

RESUMO

RESUMEN: Objetivo: Determinar la estabilidad cromática de una cerámica de feldespato monocromática utilizada en sistema CAD/CAM sometida a inmersión de diferentes soluciones de tinción. Materiales y métodos: 90 discos de cerámica feldespática monocromática, divididos en 3 grupos según solución de tinción: agua destilada, café y té. Se realizaron 3 tomas de color: el día 0, 14 y 28, con un espectrofotómetro. Para determinar la diferencia de color (ΔE*), se restó la 2da y la 1era medida para los 14 días; y la 3era y la 2da medida para los 28 días. Resultados: Los resultados se interpretaron utilizando el Índice del Departamento Nacional de Normas (NBS). La muestra inmersa en agua destilada presentó valores ΔE* 1.424 y ΔE* 1.233; la muestra en café presentó valores ΔE* 3.327 y ΔE* 3.901; la muestra inmersa en té presentó valores ΔE* 4.597 y ΔE* 5.201. Se obtuvieron diferencias significativas al comparar la estabilidad cromática en las tres soluciones de tinción a los 14 y 28 días (p<0.001). Conclusiones: Existe diferencia significativa en la estabilidad cromática de una cerámica de feldespato monocromática sometida a inmersión de diferentes soluciones de tinción. Se obtuvieron cambios de color marcados en las muestras inmersas en café y en té.


ABSTRACT: Objective: Determine the color stability of a monochromatic feldspathic ceramic used in CAD / CAM system subjected to immersion in different staining solutions. Methods and materials: 90 monochromatic feldspathic ceramic discs were divided into 3 groups according to staining solution: distilled water, coffee and tea. Three color samples were taken: on days 0, 14 and 28, with a spectrophotometer. To determine the color difference (ΔE *), the 2nd and 1st measure were subtracted for the 14 days; and the 3rd and 2nd measure for the 28 days. Results: The results were interpreted using the National Standards Department Index (NBS). The sample immersed in distilled water presented values ΔE * 1,424 and ΔE * 1,233; the sample in coffee presented values ΔE * 3,327 and ΔE * 3,901; the sample immersed in tea presented values ΔE * 4,597 and ΔE * 5,201. Significant differences were obtained when comparing the chromatic stability in the three staining solutions at 14 and 28 days (p <0.001). Conclusion: There is a significant difference in the chromatic stability of a monochromatic feldspar ceramic subjected to immersion in different staining solutions. Marked color changes were obtained in the samples immersed in coffee and tea.


Assuntos
Espectrofotometria
7.
Rev. Odontol. Araçatuba (Impr.) ; 42(2): 18-23, maio-ago. 2021. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-1252902

RESUMO

O objetivo do estudo foi realizar uma revisão narrativa da literatura para comparar os métodos visual e instrumental de seleção da cor dentária, correlacionando-os com o fator experiência e a educação continuada. Utilizou-se como base de dados a MEDLINE na qual foram aplicados os descritores "visualshade match", "color measurement", "spectrophotometer" e "tooth color determination". Os critérios de inclusão foram artigos publicados entre 2010 e 2020que abordassem uma análise comparativa entre as duas modalidades de seleção da cor dentária. Se enquadraram nos critérios de exclusão estudos que não contemplavam a temática abordada e aqueles publicados nos anos anteriores a 2010, além das revisões de literatura. No total, onze artigos foram selecionados para compor essa revisão. Os estudos demonstraram que o método instrumental apresentou maior confiabilidade e reprodutibilidade quando comparado ao método visual, isso se deve ao fato de a escolha de cor através de instrumentos eletrônicos proporcionar melhor precisão e atenuação da subjetividade. No que concerne a experiência como fator influenciador da seleção de cor, os estudos são controversos. Mesmo evidenciando melhor precisão, a estimativa instrumental apresenta limitações devido à dificuldade de aferição em função da convexidade da anatomia dentária. Desse modo, foi descrito que a associação de métodos é capaz de elevar a confiabilidade da escolha de cor, melhorando o resultado estético. Não houve consenso entre os estudos com relação à influência da experiência, no entanto, a educação continuada foi sugerida na literatura como alternativa para formar profissionais mais confiantes no processo de seleção de tonalidades(AU)


The goal of this study was to carry out a narrative review of the literature to compare the visual and instrumental methods of tooth color selection, correlating them with the experience factor and continuing education. MEDLINE was used as a database in which the descriptions such as "visual shade match", "color measurement", "spectrophotometer" and "tooth color determination" were applied. The inclusion criteria were articles published between 2010 and 2020 that addressed a comparative analysis between the two types of tooth color selection. The exclusion criteria included studies that did not contemplate the theme addressed and those published in the years prior to 2010, in addition to literature reviews. In total, eleven articles were selected to compose this review. Studies have shown that the instrumental method showed greater reliability and reproducibility when compared to the visual method, this is due to the fact that the color's choice through electronic instruments provides better precision and lessened subjectivity. Regarding experience as na influencing factor in color selection, studies are controversial. Even with better precision, the instrumental estimation has limitations due to the difficulty of measuring it due to the convexity of the dental anatomy. Thus, it was described that the association of the methods is able to increase the reliability of the color's choice, improving the aesthetic result. There was no consensus among the studies in regard to the experiment's influence, however, continuing education was suggested in the literature as an alternative in order to form more confident professionals when it comes to the shade selection process(AU)


Assuntos
Cor , Estética Dentária , Espectrofotometria
8.
Rev. med. vet. zoot ; 68(2): 124-136, mayo-ago. 2021. tab, graf
Artigo em Espanhol | LILACS, COLNAL | ID: biblio-1352098

RESUMO

RESUMEN La contaminación por metales pesados en los ecosistemas acuáticos en el planeta es una de las más severas problemáticas que comprometen la seguridad alimentaria a nivel local, regional y global. En este estudio, se aborda el problema específico de la bioconcentración de mercurio (Hg), plomo (Pb) y Zinc (Zn) en los tejidos orgánicos de 2 de las especies de peces (Ariopsis felis y Diplodus annularis) de mayor importancia alimenticia para los pobladores rivereños del río Ranchería, al norte de Colombia. Las muestras de tejido orgánico se sometieron a una digestión ácida (HNO3 y HClO 4 en relación 3:1) y la cuantificación de los metales se realizó por espectrofotometría de absorción atómica. Adicionalmente, se midieron los niveles de los metales en el sedimento, con el objeto de determinar índices de calidad medioambientales, lo que permitió determinar que los metales pesados no presentan riesgo para los organismos acuáticos que habitan en esta zona. Se encontraron diferentes valores de concentración de metales pesados: en orden decreciente, Zn > Hg > Pb, en sedimento, y Hg > Zn > Pb, en el tejido biológico. Los resultados muestran que las concentraciones de los metales pesados presentes en el tejido de los peces y en el sedimento guardan una correlación positiva y una regresión lineal estadísticamente significativa (p = 0,001, p < 0,05). La presencia de metales pesados en el sedimento del río y de bioconcentrados en los peces podría derivarse de fuentes puntuales y difusas relacionadas con actividades agrícolas, pecuarias, mineras y aguas residuales.


ABSTRACT Heavy metal pollution in aquatic ecosystems in the area is one of the most severe problems that compromise food security at the local, regional and global levels. In this study, the specific problem of the bioconcentration of mercury (Hg), lead (Pb), and Zinc (Zn) in 2 of the higher nutritional importance fish species (Ariopsis felis and Diplodus annularis) for the riverside inhabitants of the Ranchería river, in northern Colombia, is addressed. The organic tissue samples were subjected to acid digestion (HNO3 and HClO4 in a 3:1 ratio), and the quantification of metals was carried out by atomic absorption spectrophotometry. Additionally, the levels of metals in the sediment were measured, in order to determine environmental quality indices. This allow to determine that heavy metals do not present a risk to the aquatic organisms that inhabit this area. Different heavy metal concentration values were found: in decreasing order, Zn> Hg> Pb in sediment, and Hg> Zn> Pb in biological tissue. The results reveal that the concentrations of heavy metals present in fish tissue and sediment show a positive correlation, and a statistically significant linear regression (p = 0,001, p < 0,05). The presence of heavy metals in river sediment and bioconcentrates in fish could derive from point and diffuse sources related to agricultural, livestock, mining and wastewater activities.


Assuntos
Animais , Espectrofotometria Atômica , Metais Pesados , Poluição Ambiental , Peixes , Bioacumulação , Mineração , Zinco , Risco , Comissão de Ética , Chumbo , Mercúrio
9.
J. Bras. Patol. Med. Lab. (Online) ; 57: e2942021, 2021. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1279278

RESUMO

ABSTRACT Introduction: Acute paracetamol poisoning is confirmed by the determination of its serum level and allows assessing the risk of hepatotoxicity, which can be monitored by the Rumack-Matthew nomogram for the administration of the N-Acetylcysteine antidote, as well as for the prognosis of intoxication. Objective: Because of its analytical importance, we evaluated the influence of different matrices (ultrapure water, serum, and plasma) on the construction of the paracetamol calibration curve, aiming to reduce the analytical cost and facilitate its implementation in clinical and emergency laboratories. Material and methods: A standard stock solution of paracetamol of 1 mg ml-1 was obtained, from which appropriate dilutions originated the following concentrations 20, 50, 100, 150, 200, 250, and 300 mg l-1 in the different matrices, in triplicate, reading at complete after 430 nm in spectrophotometer and reproduced after three months. The results were statistically analyzed (p < 0.05). Results and discussion: Good laboratory practices include remaking the calibration curve when stock reagents are remade aiming to readjust the line equation indicated by a measuring instrument. The biological samples indicated as matrices on a calibration curve are usually serum and plasma. However, these biological products, when commercially purchased, are of high cost. Ultrapure water can replace serum and plasma in the paracetamol calibration curve according to the linearity of the curve, which showed the same trend line for the three matrices. Conclusion: The three matrices can be used in the construction of the paracetamol calibration curve, but the use of ultrapure water reduces the analysis costs.


RESUMEN Introducción: La intoxicación aguda por paracetamol se confirma mediante la determinación de su nivel sérico y permite evaluar el riesgo de hepatotoxicidad, que puede ser monitorizado mediante el nomograma de Rumack-Matthew para la administración del antídoto N-acetilcisteína, así como para el pronóstico de intoxicación. Objetivos: Por su importancia analítica, se evaluó la influencia de diferentes matrices (agua ultrapura, suero y plasma) en la construcción de la curva de calibración del paracetamol, con el objetivo de reducir el costo analítico y facilitar su implementación en laboratorios clínicos y de emergencia. Material y métodos: Se obtuvo una solución madre del estándar (stock) de paracetamol de 1 mg ml-1, de la cual se originaron diluciones adecuadas para obtener las siguientes concentraciones de 20, 50, 100, 150, 200, 250 y 300 mg l-1 con las diferentes matrices, por triplicado, con lectura a 430 nm en epectrofotômetro, reproduciéndose a los tres meses. Los resultados se analizaron estadísticamente (p < 0,05). Resultados y discusión: Las buenas prácticas de laboratorio incluyen rehacer la curva de calibración cuando se rehacen los reactivos del estándar con el fin de reajustar la ecuación lineal indicada por un instrumento de medición. Las muestras biológicas indicadas como matrices en una curva de calibración suelen ser suero y plasma. Sin embargo, estos productos biológicos cuando se compran comercialmente son de alto costo. El agua ultrapura puede reemplazar el suero y el plasma en la curva de calibración de paracetamol de acuerdo con la linealidad de la curva, que mostró la misma línea de tendencia para las tres matrices. Conclusión: Las tres matrices pueden usarse en la construcción de la curva de calibración de paracetamol, pero el uso de agua ultrapura reduce los costos de análisis.


RESUMO Introdução: A intoxicação aguda pelo paracetamol é confirmada pela determinação de seu nível sérico e permite avaliar o risco de hepatotoxicidade, que pode ser monitorado pelo nomograma Rumack-Matthew para a administração do antídoto N-acetilcisteína, bem como para o prognóstico da intoxicação. Objetivos: Diante de sua importância analítica, avaliamos a influência de diferentes matrizes (água ultrapura, soro e plasma) na construção da curva de calibração do paracetamol, visando diminuir o custo analítico e facilitar a sua implantação em laboratórios clínicos e de urgência. Material e métodos: Obtivemos uma solução estoque padrão de paracetamol de 1 mg ml-1, da qual originaram diluições apropriadas para se obter as concentrações de 20, 50, 100, 150, 200, 250 e 300 mg l-1 com as diferentes matrizes, em triplicata, com leituras em espectrofotômetro a 430 nm, sendo reproduzidas após três meses. Os resultados foram analisados estatisticamente (p < 0,05). Resultados e discussão: Nas boas práticas de laboratório, inclui-se o refazimento da curva de calibração quando os reagentes estoques são refeitos visando ao reajuste da equação de reta indicado por um instrumento de medição. As amostras biológicas indicadas como matrizes em uma curva de calibração são, usualmente, soro e plasma. Porém, esses produtos biológicos quando adquiridos comercialmente são de custo elevado. A água ultrapura pode substituir soro e plasma na curva de calibração do paracetamol em função da linearidade da curva, a qual mostrou a mesma linha de tendência para as três matrizes. Conclusão: As três matrizes podem ser utilizadas na construção da curva de calibração do paracetamol, mas o uso de água ultrapura diminui os custos da análise.

10.
Revista Científica ANMAT ; 2(Año 5): 6-15, 2021. graf., tab.
Artigo em Espanhol | BINACIS | ID: biblio-1380471

RESUMO

Haemophilus influenzae tipo b es un patógeno oportunista responsable de infecciones invasivas y graves como bacteriemia y meningitis bacteriana aguda en poblaciones susceptibles, principalmente en niños menores de 5 años de edad. Su antígeno capsular, el polirribosil-ribitol-fosfato, es un polisacárido específico del serotipo b y ha sido utilizado para la producción de vacunas, inicialmente en forma aislada, con escaso éxito debido a la pobre estimulación inmune en la población objetivo, dando una protección poco sostenida en el tiempo. Surgieron así las vacunas conjugadas, usadas actualmente, donde el polisacárido capsular se une a una proteína carrier para generar una respuesta inmune timo-dependiente, con memoria inmunológica, y apta para el uso en niños a partir de los 2 meses de edad. El polirribosil-ribitol-fosfato se caracteriza por ser una secuencia polimérica del azúcar fosfatado de largo variable, formando una mezcla con diferente abundancia de pesos moleculares. El largo de las cadenas polisacarídicas es un parámetro de calidad del proceso productivo de estas vacunas, y se controla mediante técnicas de cromatografía de exclusión molecular. El presente trabajo consistió en desarrollar una técnica analítica para la determinación de polirribosil-ribitol-fosfato en su forma libre, y conjugado a toxoide tetánico, presentes en vacunas anti Haemophilus influenzae tipo b, utilizando cromatografía de exclusión molecular acoplada a detectores por índice de refracción y por luz ultravioleta a longitudes de onda de 215 y 280 nm. El desarrollo se planteó sobre antecedentes bibliográficos que describen una metodología similar como control de la instancia de conjugación en el proceso productivo del ingrediente farmacéutico activo de vacunas anti Haemophilus influenzae tipo b. En el procedimiento se utilizaron estándares internacionales de los analitos libres y estándares de pesos moleculares, y se evaluó la capacidad del sistema para discriminar los componentes de la vacuna y detectar diferencias que podrían indicar un compromiso en la calidad de la misma.


Haemophilus influenzae type b is an opportunistic pathogen responsible for invasive and severe infections such as bacteremia and acute bacterial meningitis in susceptible populations, mainly children under 5 years of age. Its capsular antigen, polyribosylribitol-phosphate, is a specific polysaccharide of serotype b and has been used to produce vaccines, initially in isolation, with little success due to poor immune stimulation in the target population, and providing little sustained protection over time. Thus, arose the conjugated vaccines currently used, where the capsular polysaccharide binds to a carrier protein to generate a thymusdependent immune response with immunological memory and suitable for use in children from 2 months of age. Polyribosyl-ribitolphosphate is characterized by being a polymeric sequence of the phosphated sugar of variable length, forming a mixture with Emilia Ojeda Zachara*, Gisela Severino*, Ana Carolina Abba*, Patricia Aprea. Departamento del Laboratorio Nacional para el Estudio y Control de Biológicos, Dirección de Evaluación y Control de Biológicos y Radiofármacos, Instituto Nacional de Medicamentos. Administración Nacional de Medicamentos, Alimentos y Tecnología Médica, Buenos Aires. Argentina. Correspondencia: Emilia Ojeda Zachara (emilia.ojeda@anmat.gob.ar) *Estos autores contribuyeron equitativamente al desarrollo de este trabajo. Recibido: 26 de julio de 2021. Aprobado: 1 de diciembre de 2021. Revista Científica ANMAT. Año 5 (vol 2), 2021 different abundances of various molecular weights. The length of the polysaccharide chains is a quality parameter of the production process of these vaccines, and is controlled by size-exclusion chromatography techniques. The presented work consisted in developing an analytical technique for the determination of polyribosyl-ribitol-phosphate in its free form and conjugated to tetanus toxoid present in vaccines against Haemophilus influenzae type b, using size-exclusion chromatography coupled to refractive index and UV detectors at wavelengths of 215 and 280 nm. The development was based on bibliographic backgrounds that use a similar methodology as a control of the conjugation step in the production process of the active pharmaceutical ingredient of anti-Haemophilus influenzae type b vaccines. In the procedure, international standards for free analytes and molecular weight standards were used, and the ability of the system to discriminate the vaccine components and to detect differences that could indicate a compromise in the quality of this vaccine was evaluated


Assuntos
Espectrofotometria Ultravioleta , Cromatografia em Gel , Vacinas Anti-Haemophilus
11.
Rev. cuba. estomatol ; 57(4): e3376, Oct.-Dec. 2020. tab, graf
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1144452

RESUMO

RESUMEN Introducción: El blanqueamiento intracoronal es una alternativa mínimamente invasiva que permite devolver el color a dientes no vitales tincionados. La estabilidad del color logrado es fundamental para evaluar la predictibilidad de este tipo de tratamiento. Objetivo: Evaluar la estabilidad del color 3 años después del blanqueamiento intracameral con peróxido de hidrógeno y carbamida a diferentes concentraciones. Métodos: Se utilizaron 44 premolares extraídos por indicación ortodóncica, los cuales fueron tratados endodónticamente y pigmentados artificialmente con cromógenos sanguíneos. Las muestras fueron divididas aleatoriamente en 4 grupos de estudio (n = 11) siendo: grupo A: peróxido de carbamida 37 por ciento, grupo B: peróxido de hidrógeno 35 por ciento, grupo C: peróxido de carbamida 100 por ciento y grupo D: control; para luego realizar 4 aplicaciones de agente blanqueador con un intervalo de 4 días entre cada aplicación. El registro del color se realizó mediante espectrofotometría, lo que permitió obtener los valores CIE L*a*b* para calcular la variación total de color entre los parámetros iniciales y finales del tratamiento, así como el control a los 3 años. Resultados: Los resultados fueron analizados mediante las pruebas de Shapiro-Wilks, ANOVA y Mann-Whitney, sin registrar diferencias significativas en la variación total de color al control de los 3 años (p > 0,05). Conclusión: Los resultados del blanqueamiento intracoronal, independiente del tipo y concentración del agente utilizado en este estudio son estables en el tiempo y cualquier variación regresiva de color debe ser atribuida a factores extrínsecos(AU)


ABSTRACT Introduction: Intracoronal whitening is a minimally invasive procedure to restore natural color to stained non-vital teeth. The color stability achieved is fundamental to evaluate the predictability of this type of treatment. Objective: Evaluate color stability 3 years after intracameral whitening with carbamide and hydrogen peroxide at various concentrations. Methods: A total 44 premolars were used which had been extracted by orthodontic indication. The premolars were treated endodontically and artificially pigmented with blood chromogenes. The samples were randomly divided into 4 study groups (n = 11): Group A: 37 percent carbamide peroxide, Group B: 35 percent hydrogen peroxide, Group C: 100 percent carbamide peroxide and Group D: control. Four applications were then made of the whitening agent with a 4-days' separation between them. Color was recorded by spectrophotometry, obtaining the values CIE L*a*b* to estimate total color variation between the initial and final parameters of the treatment, as well as control at 3 years. Results: The results were analyzed with Shapiro-Wilk, ANOVA and Mann-Whitney tests, not finding any significant differences in total color variation with respect to the 3 years' control (p > 0.05). Conclusion: The results of the intracoronal whitening studied are stable throughout time, regardless of the type and concentration of the agent used, and any regressive color variation should be attributed to extrinsic factors(AU)


Assuntos
Humanos , Espectrofotometria/métodos , Clareamento Dental/efeitos adversos , Dente não Vital/tratamento farmacológico , Peróxido de Carbamida/uso terapêutico , Peróxido de Hidrogênio/uso terapêutico
12.
J. oral res. (Impresa) ; 9(6): 490-499, dic. 31, 2020. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1178945

RESUMO

Introduction: This study aimed to evaluate the effect of dentin surface treatment with 37% phosphoric acid or 17% ethylenedia-minetetraacetic acid (EDTA) before Internal Bleaching with 35% hydrogen peroxide using the walking bleach technique. Material and Methods: This experimental in vitro study used 66 human premolars extracted for orthodontic reasons, which were debrided, endodontically prepared, and pigmented with chromogens derived from blood decomposition. The samples were randomly divided into three groups (n=22). Group A: bleaching agent without dentin conditioning; group B: bleaching agent in dentin conditioned with phosphoric acid 37%; group C: bleaching agent in dentin conditioned with 17% EDTA. 4 applications of bleaching agent were used with a separation of 4 days between each session. The initial color (baseline) and after each application was determined by spectrophotometry, recording the CIE L*a*b* values and the total color variation between the initial parameters and the different evaluation times. Results: Data were statistically analyzed with the Wilcoxon test. This showed statistically significant differences for the total variation of the color between the study groups, with the control group in no case inferior to the rest. Conclusion: The application of 37% phosphoric acid increased the effectiveness of the bleaching agent when compared to 17% EDTA. However, these did not increase the effectiveness compared to the application of the bleaching agent without a previous dentin surface treatment.


Introducción: El objetivo de este estudio fue evaluar el efecto del tratamiento de superficie dentinaria con ácido fosfórico al 37% o EDTA al 17% previo al blanqueamiento Interno con peróxido de hidrógeno al 35% por medio de la técnica Walking Bleach. Material y Métodos:Para este estudio experimental in vitro, se utilizaron 66 premolares humanos extraídos por indicación ortodóncica, los cuales fueron desbridados, preparados endodónticamente, y pigmentados con cromógenos derivados de la descomposición sanguínea. Las muestras fueron divididas aleatoriamente en 3 grupos (n=22). Grupo A: agente blanqueador sin acondicionamiento dentinario, grupo B: agente blanqueador en dentina acondicionada con ácido fosfórico 37% y grupo C: agente blanqueador en dentina acondicionada con EDTA 17%. Se utilizaron 4 aplicaciones de agente blanqueador con una separación de 4 días entre cada sesión. El color inicial (baseline) y tras cada aplicación fue determinado mediante espectrofotometría, registrando los valores CIE L*a*b* y la variación total de color entre los parámetros iniciales y los diferentes tiempos de evaluación. Resultados: Los datos fueron analizados estadísticamente con la prueba de Wilcoxon, arrojando diferencias estadísticamente significativas para la variación total del color entre los grupos de estudio, siendo en ningún caso el grupo control inferior al resto. Conclusión: La aplicación de ácido fosfórico al 37% aumenta la eficacia del agente blanqueador al compararlo con el EDTA 17%, sin embargo, no aumentan la eficacia respecto a la aplicación del agente blanqueador sin un tratamiento de superficie dentinaria previo.


Assuntos
Humanos , Ácido Edético/química , Cor , Esmalte Dentário/química , Dentina/química , Peróxido de Hidrogênio/química , Espectrofotometria , Dente Pré-Molar , Técnicas In Vitro , Chile , Ensaio Clínico
13.
Dent. press endod ; 10(3): 88-93, Sept-Dec.2020. Tab
Artigo em Inglês | LILACS | ID: biblio-1348054

RESUMO

Objetivo: O objetivo do presente estudo foi avaliar clinicamente a descoloração da coroa dentária após obturação do canal radicular com diferentes cimentos endodônticos. Métodos: Trinta e dois dentes foram tratados endodonticamente e obturados com AH Plus (AHP), Endofill (END), MTA Fillapex (MTA) ou Sealer 26 (SEA), divididos em oito pacientes por grupo. O registro das cores foi realizado com um espectrofotômetro antes da intervenção (T0 ), aos 30 (T1 ) e aos 90 dias após a intervenção (T2 ). As avaliações foram feitas no centro da coroa dentária e a variação de cor (ΔE) foi calculada por meio da Commission International de l'Eclai- rage (CIE) L*a*b. Um operador, especialista em Endodontia, realizou os procedimentos clínicos. Os dados foram submetidos a medidas repetidas ANOVA e teste de Tukey (Δ=5%). Resultados: Não houve diferença estatisticamente significativa na variação de cores entre os cimentos (AHP ΔE=4,11; END ΔE = 6,34; SEA ΔE = 8,77 e MTA ΔE = 12,15), p>0,05. Porém, houve diferença entre os períodos analisados (T1ΔE= 5,65; T2 ΔE = 10,02). Conclusões: Dentro das limitações deste estudo, todos os cimentos endodônticos causaram alterações cromáticas clinicamente perceptíveis na coroa dentária. No entanto, o AH Plus promoveu menos alterações cromáticas na coroa dentária (AU).


Introduction: The aim of this study was to evaluate the crown discoloration after root canal filling with different endodontic cements clinically. Methods: Thirty-two teeth were endodontically treated and filled with AH Plus (AHP), Endofill (END), MTA Fillapex (MTA), or Sealer 26 (SEA), divided into eight patients per group. Color recording was performed with a spectrophotometer before the intervention (T0 ) and at 30 (T1 ) and 90 days post-intervention (T2 ). The evaluations were done in the center of the dental crown and color variation (ΔE) was calculated by means of the Commission International de IEclairage (CIE) L*a*b. The data were subjected to repeated measures ANOVA and Tukeys test (alpha=5%). Results: There was no statistically significant difference in color variation between the cements (AHP ΔE=4.11; END ΔE=6.34; SEA ΔE=8.77, and MTA ΔE=12.15), p>0.05. However, there was a difference between the periods tested (T1 ΔE=5.65; T2 ΔE=10.02). Conclusions: All tested endodontic cements altered the color of dental crowns (AU).


Assuntos
Humanos , Obturação do Canal Radicular , Descoloração de Dente , Coroa do Dente , Espectrofotometria , Análise de Variância
14.
Rev. colomb. ciencias quim. farm ; 49(2): 355-373, May-Aug. 2020. tab, graf
Artigo em Português | LILACS-Express | LILACS | ID: biblio-1144356

RESUMO

RESUMO A pesquisa descreve a reação espectrofotométrica do complexo Cu(II)-PAN (1-(2-piridilazo)-2-naftol) e determina a concentração de cobre (II) em aguardente de mandioca (Tiquira). Para isso, dimensionamos a reação para os estudos de absorção do complexo, pH, estabilidade, proporção estequiométrica, interferentes, correlação e recuperação. Após essa etapa, determinamos a concentração de cobre(II) em cinco amostras de bebidas destiladas artesanalmente de cinco municípios do Estado do Maranhão. O resultados mostram que o complexo absorve em 548 nm em pH 6, é estável em um tempo de 7 horas em proporções estequiométrica mínima de 1:1 do ligante e metal, possui limite de detecção em 3,3 X 10-2 mg L-1, faixa de linearidade de 1 X 10-6 a 1 X 10-5 mol L-1, correlação (R2= 0,9990), desvio padrão=0,0035 e recuperação em 104,54 ± 7,01 e os principais íons interferentes são o ferro (III) e o cobalto (II). Na aguardente, constatamos que o teor de cobre está acima do permitido pela legislação brasileira.


SUMMARY The search describes the spectrophotometric reaction of the Cu (II)-PAN (1-(2-pyridilazo) -2-naphthol) complex and determines the concentration of copper (II) in manioc spirit (Tiquira). For this, we dimensioned the reaction for the studies of complex absorption, pH, stability, stoichiometric ratio, interferences, correlation, and recovery. After this step, we determined the concentration of copper (II) in five samples of beverages distilled artisanal from five municipalities of the State of Maranhão. The results show that the complex absorbs at 548 nm at pH 6, is stable at a time of 7 hours in minimum 1:1 stoichiometric proportions of the binder and metal, has a detection limit in 3.3 X 10-2 mg L-1, range (R2= 0.9990), standard deviation= 0.0035 and recovery at 104.54 ± 7.0, and the main interfering ions are iron (III) and cobalt (II). In the brandy, we find that the copper content is above that allowed by Brazilian legislation.

15.
Rev. bras. anestesiol ; 70(4): 388-397, July-Aug. 2020. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1137193

RESUMO

Abstract Background and objectives: The measurement of hemoglobin concentration (Hb) by co-oximetry is an innovative technique that offers efficiency and agility in the processing of information regarding the measurement of Hb obtained through continuous, non-invasive and rapid monitoring. Because of this attribute, it avoids unnecessary exposures of the patient to invasive procedures by allowing a reduction in the number of blood samples for evaluation and other unnecessary therapies. It also helps to make decisions about the need for transfusion and how to handle it. The objective of this study is to compare the performance offered to obtain Hb values between the Masimo Corporation (Irvine, CA, USA) instrument and the standard gold tool (laboratory examination). Contents: The study corresponds to a systematic review followed by meta-analysis, which included fully registered full-text clinical trials published from 1990 to 2018. PubMed, Cochrane, Medline, Embase and Web of Science databases were investigated. The mean overall difference found between the non-invasive and invasive methods of hemoglobin monitoring was 0.23 (95% CI -0.16, 0.62), that is, it did not present statistical significance (p = 0.250). The results of the analysis of heterogeneity within and between the studies indicated high levels of inconsistency (Q = 461.63, p < 0.0001, I2 = 98%), method for Hb values. Conclusions: Although the mean difference between noninvasive measurements of Hb and the gold standard method is small, the co-oximeter can be used as a non-invasive "trend" monitor in detecting unexpected responses at Hb levels.


Resumo Justificativa: A medida da concentração de hemoglobina (Hb)por co-oximetria é uma técnica inovadora que oferece eficiência e agilidade no processamento das informações referentes à medida da concentração de hemoglobina obtida por meio de monitorização contínua, não-invasiva e rápida. Por conta desse atributo, evita exposições desnecessárias do paciente a procedimentos invasivos ao possibilitar redução da quantidade de amostras sanguíneas para avaliação e de outras terapêuticas desnecessárias. Além disso, auxilia a tomada de decisões quanto à necessidade de transfusão e quanto ao manejo da mesma. Objetivo: Comparar o desempenho oferecido para a obtenção dos valores de concentração de hemoglobina entre medida não invasiva da Hb e a ferramenta padrão ouro (exame laboratorial). Conteúdo: O estudo corresponde a uma revisão sistemática seguida de metanálise que incluiu ensaios clínicos devidamente registrados com texto completo, publicados a partir de 1990 até 2018. Foram investigadas as bases de dados PubMed, Cochrane, Medline, Embase e Web Of Science. A diferença média global encontrada entre os métodos não invasivo e invasivo de monitorização da hemoglobina foi de 0,23 (95% IC -0,16; 0,62), ou seja, não apresentou significância estatística (p = 0,250). Os resultados da análise de heterogeneidade dentro e entre os estudos, apontou níveis elevados de inconsistência (Q = 461,63, p< 0,0001, I2 = 98%). Conclusão: Embora a diferença média entre as medidas não invasivas da Hb e o método padrão ouro sejam pequenas, o co-oxímetro pode ser utilizado como um monitor não invasivo de "tendência" na detecção de alterações inesperadas nos níveis de Hb.


Assuntos
Humanos , Hemoglobinas/análise , Oximetria/métodos , Monitorização Fisiológica/métodos , Projetos de Pesquisa , Transfusão de Sangue , Ensaios Clínicos como Assunto/métodos
16.
Braz J Anesthesiol ; 70(4): 388-397, 2020.
Artigo em Português | MEDLINE | ID: mdl-32682505

RESUMO

BACKGROUND AND OBJECTIVES: The measurement of Hb by co-oximetry is an innovative technique that offers efficiency and agility in the processing of information regarding the measurement of Hemoglobin concentration (Hb) obtained through continuous, non-invasive and rapid monitoring. Because of this attribute, it avoids unnecessary exposures of the patient to invasive procedures by allowing a reduction in the number of blood samples for evaluation and other unnecessary therapies. It also helps to make decisions about the need for transfusion and how to handle it. The objective of this study is to compare the performance offered to obtain Hb values between the Masimo Corporation (Irvine, CA, USA) instrument and the standard gold tool (laboratory examination). CONTENTS: The study corresponds to a systematic review followed by meta-analysis, which included fully registered full-text clinical trials published from 1990 to 2018. PubMed, Cochrane, Medline, Embase and Web of Science databases were investigated. The mean overall difference found between the non-invasive and invasive methods of hemoglobin monitoring was 0.23 (95% CI -0.16, 0.62), that is, it did not present statistical significance (p = 0.250). The results of the analysis of heterogeneity within and between the studies indicated high levels of inconsistency (Q = 461.63, p < 0.0001, I2 = 98%), method for Hb values. CONCLUSIONS: Although the mean difference between noninvasive measurements of Hb and the gold standard method is small, the co-oximeter can be used as a non-invasive "trend" monitor in detecting unexpected responses at Hb levels.


Assuntos
Hemoglobinas/análise , Monitorização Fisiológica/métodos , Oximetria/métodos , Transfusão de Sangue , Ensaios Clínicos como Assunto/métodos , Humanos , Projetos de Pesquisa
17.
Belo Horizonte; s.n; 2020. 76 p. ilus.
Tese em Português | LILACS, BBO - Odontologia | ID: biblio-1392052

RESUMO

Este estudo avaliou o efeito do contato com a saliva in vitro e do fluxo salivar normal e reduzido in situ na rugosidade e na composição de cálcio e fósforo do esmalte, após clareamento com peróxido de hidrogênio 35%. Espécimes obtidos de terceiros molares (5 x 5 mm) foram divididos em 5 grupos (n=15), G1: não clareado e não exposto à saliva; G2: clareado e não exposto à saliva; G3: clareado e mantido em saliva natural in vitro, G4: clareado e mantido em saliva humana in situ em voluntários com fluxo salivar normal, G5: clareado e mantido em saliva humana in situ em voluntários com baixo fluxo salivar. A rugosidade (Ra, Rz), a proporção cálcio/fósforo e as porcentagens de cálcio e fósforo do esmalte foram avaliadas, respectivamente, por perfilometria a laser 3D e espectroscopia de energia dispersiva por raios X, antes do clareamento (T1), após o clareamento (T2) e após contato com saliva (T3). A saliva dos participantes foi coletada e o fluxo salivar foi medido para alocação nos grupos 4 e 5. O pH salivar e a capacidade tampão foram avaliados por fitas medidoras.As concentrações de cálcio e fósforo salivar foram determinadas por espectrofotometria de absorbância. Os dados foram analisados por testes não paramétricos para análise entre grupos e entre os tempos. Um modelo de regressão linear foi ajustado para a variável dependente rugosidade do esmaltedos grupos 4 e 5 em T3, considerando as covariáveis fluxo salivar, pH, capacidade tampão e concentração de cálcio e fósforo salivar (p<0,05). Não houve diferença de rugosidade (Ra, Rz) entre grupos em T1 (p>0,05). Em T2, G1 diferiu de todos os grupos. Em T3, G5=G2>G3=G4=G1. Para G1, a rugosidade de T1=T2=T3. Para G2 e G5 T10,05). A rugosidade Ra foi em média 0,14 menor no grupo de fluxo salivar normal comparado ao grupo de fluxo reduzido, enquanto Rz foi em média 1,95 menor no grupo fluxo salivar normal. Conclui-se que o contato com a saliva humana in vitro e com o fluxo salivar normal in situ restabeleceu a rugosidade do esmalte. O baixo fluxo salivar in situ não restabeleceu a rugosidade inicial. O clareamento dentário e o contato com a saliva humana não alteram a proporção cálcio/fósforo e nem suas porcentagens isoladas no esmalte. A recuperação da rugosidade do esmalte clareado foi maior em fluxo salivar normal que em baixo fluxo salivar, independentemente do pH salivar e de sua capacidade tampão.


This study evaluated the effect of saliva in vitro and regular or low salivary flow in situ on roughness, calcium/phosphorus ratio and calcium and phosphorus percentages of the enamel bleached with 35% hydrogen peroxide. Seventy-five specimens of third molars were divided in 5 groups, G1: Not bleached and not exposed to saliva; G2: Bleached and not exposed to saliva; G3: Bleached and stored in natural saliva in vitro, G4: Bleached and exposed to human saliva in situ in normal salivary flow participants, G5: Bleached and exposed to human saliva in situ in low salivary flow participants. Roughness (Ra, Rz) was evaluated with a 3D laser non-contact profilometer. Calcium/phosphorus ratio and calcium and phosphorus percentages were determined with energy- dispersive X-Ray spectrophotometry. These evaluations were performed before bleaching (T1), after bleaching (T2) and after the contact with saliva (T3). Participants saliva was collected and salivary flow was measured for their allocation in groups 4 and 5. Salivary pH and buffering capacity were evaluated with measuring tapes. Salivary calcium and phosphorus concentrations were determined by absorbance spectrophotometry. Data were analyzed by nonparametric tests for the analysis between groups and times. A model of linear regression was adjusted for the dependent variable enamel roughness of groups 4 and 5 in T3, considering the covariables salivary flow, pH, buffering capacity and salivary calcium and phosphorus concentration (p<0.05). Roughness was similar among groups in T1. In T2, G1 differed from all groups. In T3, G5=G2>G3=G4=G1. For G1, roughness of T1=T2=T3. For G2 and G5 T10.05), nor between the moments of evaluation T1, T2 and T3 (p>0.05). Ra and Rz were, respectively, 0.14 and 1.95 lower with normal salivary flow than reduced salivary flow. It was concluded that the contact with the human saliva in vitro and normal salivary flow in situ reestablished the enamel roughness to the original values, but the low salivary flow did not. Dental bleaching and the contact with human saliva cannot modify calcium/phosphorus ratio nor their isolated percentages. Recovery of bleached enamel roughness was higher in normal salivary flow than low salivary flow, regardless of saliva pH and buffering capacity.


Assuntos
Saliva , Espectrofotometria , Clareamento Dental , Esmalte Dentário , Peróxido de Hidrogênio
18.
Rev. colomb. ciencias quim. farm ; 48(1): 29-43, jan.-abr. 2019. tab, graf
Artigo em Português | LILACS | ID: biblio-1042797

RESUMO

RESUMO Este trabalho descreveu e comparou quatro estudos entre si que utilizaram métodos automáticos em fluxo com detecção espectrofotométrica e a reação de oxidação do diclofenaco para determinar diclofenaco em formulações farmacêuticas e fluidos corporais. Para isso, utilizamos os seguintes artigos: Versatility of a multicommuted flow system in the spectrometric determination of three analytes, Sequential injection spectrophotometric method for the assay of anti-inflammatory diclofenac sodium in pharmaceutical preparations, Screening of conditions controlling spectrophotometric sequential injection analysis e Sequential injection spectrophotometric determination of diclofenac in urine and pharmaceutical formulations e detalhamos as metodologias empregadas, os resultados, conclusões obtidas e comparamos entre eles os limites de detecção, desvio padrão relativo e a frequência analítica. Os resultados mostraram diferenças significativas entre métodos empregados e a utilização do Sistema automático do tipo Análise por Injeção Sequencial, apesar deste possuir menor frequência analítica.


SUMMARY This study described and compared four studies that used automatic flow methods with spectrophotometric detection and the oxidation reaction of diclofenac to determine diclofenac in pharmaceutical formulations and body fluids. For this, the following articles were used: Versatility of a multicommuted flow system in the spectrometric determination of three analytes, Sequential injection spectrophotometric method for the assay of anti-inflammatory diclofenac sodium in pharmaceutical preparations, Screening of conditions controlling spectrophotometric sequential injection analysis and Sequential injection spectrophotometric determination of diclofenac in urine and pharmaceutical formulations and we detail the methodologies used, the results, the conclusions obtained and compare the limits of detection, relative standard deviation and analytical frequency. The results showed significant differences between the employed methods and the use of the Automatic System of the Sequential Injection Analysis type, although this one has a lower analytical frequency.

19.
Rev. mex. ing. bioméd ; 40(1): e201802EE1, Jan.-Apr. 2019. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-1043137

RESUMO

Resumen La descentralización de laboratorios clínicos, se encuentra en desarrollo, lo anterior ha llevado a diseñar instrumentos que ofrecen resultados rápidos, confiables y al lado del paciente, esta tendencia se le conoce como prueba en el punto de atención (point of core testing POCT) y brinda la posibilidad de dar un seguimiento inmediato al padecimiento. El objetivo de esta investigación fue la implementación de un medidor de absorbancia, empleando la estructura de un microscopio óptico, al cual se le ha adaptado un filtro de luz, y una cámara digital. Lo anterior permite obtener valores de intensidad promedio de imágenes sólidas microscópicas de reacciones enzimáticas, y a partir de ellas estimar absorbancia o concentración. Como resultados se presentan rectas de calibración de absorbancia y mediciones de concentraciones para los casos de violeta de genciana, un kit de glucosa oxidasa y muestras problemas de pacientes voluntarios. Concluimos que existe un error de medición menor de ±1mg/dL comparados con las mediciones de un lector de placas de Elisa y un analizador de química sanguínea semiautomatizado. Teniendo en cuenta lo anterior el sistema resulta ser una alternativa viable para la estimación de absorbancia y aumenta la funcionalidad de microscopios ópticos en clínicas de salud.


Abstract The decentralization of clinical laboratories is under development, which has led to the design of instruments that offer fast, reliable and patient-side results, this trend is known as point of core testing (POCT) and It offers the possibility of giving an immediate follow-up to the disease. The objective of this investigation was the implementation of an absorbance meter, using the structure of an optical microscope, to which a light filter and a digital camera have been adapted. This allows to obtain values of average intensity of solid images of enzymatic reactions, and from them to estimate absorbance or concentration. As results, we present absorbance calibration lines and concentration measurements for cases of gentian violet, a glucose oxidase kit and samples of volunteer patients. We conclude that there is a measurement error of less than ± 1mg / dl compared with the measurements of an Elisa plate reader and a semi-automated blood chemistry analyzer. Taking into account the above, the system turns out to be a viable alternative for estimating absorbance and increasing the functionality of optical microscopes in health clinics.

20.
Rev. med. vet. (Bogota) ; (37): 57-63, jul.-dic. 2018. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1094057

RESUMO

Resumen El plomo es uno de los metales pesados más tóxicos para los seres vivos, lo cual constituye una problemática a escala global. Este metal se encuentra de manera natural en el medio ambiente. Puede permanecer por largos periodos en tejidos animales y producir alteraciones fisiológicas, comportamentales e incluso la muerte. Uno de los grupos taxonómicos más afectados son las aves, especialmente aquellas especies que se encuentran en la parte superior de la cadena alimenticia, debido a su susceptibilidad a la bioacumulación de metales pesados. Sin embargo, en Suramérica existe escasa información sobre la exposición de plomo en catártidos. El objetivo de esta investigación fue determinar concentraciones basales de plomo en catártidos mantenidos en condiciones de cautiverio en Colombia. Para ello se analizaron muestras sanguíneas de 9 reyes gallinazos (Sarcoramphus papa) y 7 cóndores de los Andes (Vultur gryphus) de tres zoológicos por medio de espectrofotometría de absorción atómica. Los resultados sugieren que 15 de 16 ejemplares contienen concentraciones de plomo. El zoológico B tuvo el mayor promedio (2,65 ± 1,00 µg/dL), seguido del zoológico C (1,87 ± 0,63 µg/dL) y del zoológico A (0,8 ± 0,89 µg/dL). El promedio para S. papa fue de 2,11 ± 0,42 µg/dL, mientras que el de V. gryphus fue de 1,89 ± 1,52 µg/dL. Se concluye que aunque existe una diferencia significativa (p = 0,01) entre los zoológicos muestreados y se detectaron concentraciones de plomo en el 93,75 % de la población, estas son bajas comparadas con las reportadas por los estudios.


Abstract Lead is one of the most toxic heavy metals for living beings, which is a problem on a global scale. This metal is found naturally in the environment. It can remain for long periods in animal tissues, and produce physiological and behavioral alterations, even death. One of the most affected taxonomic groups are birds, especially those species that are at the top of the food chain, due to their susceptibility to the bioaccumulation of heavy metals. However, in South America, there is little information on lead exposure in birds from the New World vulture (Cathartidae) family. This research aimed to determine basal concentration levels of lead in birds from the Cathartidae family kept in captivity conditions in Colombia. To the effect, blood samples of nine king vultures (Sarcoramphus papa) and seven Andean condors (Vultur gryphus) were analyzed from three zoos using atomic absorption spectrophotometry. The results suggest that 15 out of 16 specimens contain blood lead concentrations. Zoo B had the highest average (2.65 ± 1.00 μg/dL), followed by Zoo C (1.87 ± 0.63 μg/dL), and zoo A (0.8 ± 0.89 μg/dL). The average for S. papa was 2.11 ± 0.42 μg/dL, while for V. gryphus it was 1.89 ± 1.52 μg/dL. It is concluded that although there is a significant difference (p = 0.01) among the sampled zoos, and lead concentrations were detected in 93.75% of the population, these are low compared to levels reported by other studies.


Resumo O chumbo é um dos metais pesados mais tóxicos para os seres vivos, o qual constitui uma problemática na escala global. Este metal se encontra naturalmente no meio ambiente. Pode permanecer por longos períodos em tecidos animais e produzir alterações fisiológicas, comportamentais e inclusive a morte. Um dos grupos taxonômicos mais afetados são as aves, especialmente aquelas espécies que se encontram na parte superior da cadeia alimentícia, devido a sua suscetibilidade à bioacumulação de metais pesados. No entanto, na América do Sul existe escassa informação sobre a exposição de chumbo em catárticos. O objetivo desta investigação foi determinar concentrações basais de chumbo em catárticos mantidos em condições de cativeiro na Colômbia. Para isso foram analisadas amostras sanguíneas de 9 urubus reis (Sarcoramphus papa) e 7 condores dos Andes (Vultur gryphus) de três zoológicos por média de espectrofotometria de absorção atômica. Os resultados sugerem que 15 de 16 exemplares contém concentrações de chumbo. O zoológico B teve a maior média (2,65 ± 1,00 µg/dL), seguida do zoológico C (1,87 ± 0,63 µg/dL) e do zoológico A (0,8 ± 0,89 µg/dL). A média para S. papa foi de 2,11 ± 0,42 µg/dL, enquanto que o de V. gryphus foi de 1,89 ± 1,52 µg/dL. Se conclui que ainda existe uma diferença significativa (p = 0,01) entre os zoológicos amostrados e se detectaram concentrações de chumbo no 93,75 % da população, estas são baixas comparadas com as relatadas pelos estudos.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...